P. Actis, A. Rogers, J. Nivala, B. Vilozny, R. A. Seger et al., Reversible thrombin detection by aptamer functionalized STING sensors, Biosensors and Bioelectronics, vol.26, issue.11, pp.4503-4507, 2011.
DOI : 10.1016/j.bios.2011.05.010

B. R. Baker, R. Y. Lai, M. S. Wood, E. H. Doctor, A. J. Heeger et al., An Electronic, Aptamer-Based Small-Molecule Sensor for the Rapid, Label-Free Detection of Cocaine in Adulterated Samples and Biological Fluids, Journal of the American Chemical Society, vol.128, issue.10, pp.3138-3139, 2006.
DOI : 10.1021/ja056957p

J. M. Becker and M. Wilchek, Inactivation by avidin of biotin-modified bacteriophage, Biochimica et Biophysica Acta (BBA) - General Subjects, vol.264, issue.1, pp.165-170, 1972.
DOI : 10.1016/0304-4165(72)90127-4

C. Berens, A. Thain, and R. Schroeder, A tetracycline-binding RNA aptamer, Bioorganic & Medicinal Chemistry, vol.9, issue.10, pp.2549-2556, 2001.
DOI : 10.1016/S0968-0896(01)00063-3

D. H. Burke, D. C. Hoffman, A. Brown, M. Hansen, A. Pardi et al., RNA aptamers to the peptidyl transferase inhibitor chloramphenicol, Chemistry & Biology, vol.4, issue.11, pp.833-843, 1997.
DOI : 10.1016/S1074-5521(97)90116-2

G. Castillo, I. Lamberti, L. Mosiello, and T. Hianik, Impedimetric DNA Aptasensor for Sensitive Detection of Ochratoxin A in Food, Electroanalysis, vol.37, issue.3, pp.512-520, 2012.
DOI : 10.1002/elan.201100485

L. N. Cella, W. Chen, and A. Mulchandani, Chapter 4 aptamerbased biosensor for environmental monitoring, Nucleic Acid Biosensors for Environmental Pollution Monitoring, pp.61-81, 2011.

L. N. Cella, P. Sanchez, W. Zhong, N. V. Myung, W. Chen et al., Nano Aptasensor for Protective Antigen Toxin of Anthrax, Analytical Chemistry, vol.82, issue.5, pp.2042-2047, 1021.
DOI : 10.1021/ac902791q

S. Centi, S. Tombelli, M. Minunni, and M. Mascini, Aptamer-Based Detection of Plasma Proteins by an Electrochemical Assay Coupled to Magnetic Beads, Analytical Chemistry, vol.79, issue.4, pp.1466-1473, 2007.
DOI : 10.1021/ac061879p

B. Chakraborty, Z. Jiang, Y. Li, Y. , and H. , Rational design and performance testing of aptamer-based electrochemical biosensors for adenosine, Journal of Electroanalytical Chemistry, vol.635, issue.2, pp.75-82, 2009.
DOI : 10.1016/j.jelechem.2009.08.006

H. S. Chang, K. H. Choo, B. Lee, and S. J. Choi, The methods of identification, analysis, and removal of endocrine disrupting compounds (EDCs) in water, Journal of Hazardous Materials, vol.172, issue.1, pp.1-12, 2009.
DOI : 10.1016/j.jhazmat.2009.06.135

J. Chen, J. Jiang, X. Gao, G. Liu, G. Shen et al., A New Aptameric Biosensor for Cocaine Based on Surface-Enhanced Raman Scattering Spectroscopy, Chemistry - A European Journal, vol.86, issue.27, pp.8374-8382, 2008.
DOI : 10.1002/chem.200701307

Z. Chen, L. Li, X. Mu, H. Zhao, and L. Guo, Electrochemical aptasensor for detection of copper based on a reagentless signal-on architecture and amplification by gold nanoparticles, Talanta, vol.85, issue.1, pp.730-735, 2011.
DOI : 10.1016/j.talanta.2011.04.056

A. K. Cheng, B. Ge, Y. , and H. Z. , Aptamer-Based Biosensors for Label-Free Voltammetric Detection of Lysozyme, Analytical Chemistry, vol.79, issue.14, pp.5158-5164, 2007.
DOI : 10.1021/ac062214q

J. A. Cruz-aguado and G. Penner, Determination of Ochratoxin A with a DNA Aptamer, Journal of Agricultural and Food Chemistry, vol.56, issue.22, pp.10456-10461, 2008.
DOI : 10.1021/jf801957h

A. D. Ellington, J. W. Szostak, G. Zhao, H. Shi, M. Liu et al., In vitro selection of RNA molecules that bind specific ligands A highly selective electrochemical impedance spectroscopy-based aptasensor for sensitive detection of acetamiprid, Nature Biosens. Bioelectron, vol.346, issue.43, pp.818-822, 1990.

E. E. Ferapontova, E. M. Olsen, K. V. Gothelf, M. C. Buzzeo, and J. K. Barton, An RNA Aptamer-Based Electrochemical Biosensor for Detection of Theophylline in Serum, Journal of the American Chemical Society, vol.130, issue.13, pp.4256-4258, 1021.
DOI : 10.1021/ja711326b

M. C. Gwee, Can tetracycline-induced fatty liver in pregnancy be attributed to choline deficiency?, Medical Hypotheses, vol.9, issue.2, pp.157-162, 1982.
DOI : 10.1016/0306-9877(82)90131-1

C. L. Hamula, J. W. Guthrie, H. Zhang, X. Li, L. et al., Selection and analytical applications of aptamers, TrAC Trends in Analytical Chemistry, vol.25, issue.7, pp.681-691, 2006.
DOI : 10.1016/j.trac.2006.05.007

K. Han, L. Chen, Z. Lin, L. , and G. , Target induced dissociation (TID) strategy for the development of electrochemical aptamer-based biosensor, Electrochemistry Communications, vol.11, issue.1, 2009.
DOI : 10.1016/j.elecom.2008.10.054

A. Hayat and S. Andreescu, Nanoceria Particles As Catalytic Amplifiers for Alkaline Phosphatase Assays, Analytical Chemistry, vol.85, issue.21, pp.10028-10032, 2013.
DOI : 10.1021/ac4020963

A. Hayat, S. Andreescu, M. , and J. , Design of PEG-aptamer two piece macromolecules as convenient and integrated sensing platform: Application to the label free detection of small size molecules, Biosensors and Bioelectronics, vol.45, pp.168-173, 2013.
DOI : 10.1016/j.bios.2013.01.059

A. Hayat, L. Barthelmebs, A. Sassolas, M. , and J. L. , An electrochemical immunosensor based on covalent immobilization of okadaic acid onto screen printed carbon electrode via diazotization-coupling reaction, Talanta, vol.85, issue.1, pp.513-518, 2011.
DOI : 10.1016/j.talanta.2011.04.034

A. Hayat, L. Barthelmebs, A. Sassolas, M. , and J. L. , Development of a novel label-free amperometric immunosensor for the detection of okadaic acid, Analytica Chimica Acta, vol.724, pp.92-97, 2012.
DOI : 10.1016/j.aca.2012.02.035

A. Hayat, W. Haider, M. Rolland, M. , and J. , Electrochemical grafting of long spacer arms of hexamethyldiamine on a screen printed carbon electrode surface: application in target induced ochratoxin A electrochemical aptasensor, The Analyst, vol.24, issue.10, pp.2951-2957, 1039.
DOI : 10.1039/c3an00158j

A. Hayat, N. Paniel, A. Rhouati, J. L. Marty, and L. Barthelmebs, Recent advances in ochratoxin A-producing fungi detection based on PCR methods and ochratoxin A analysis in food matrices, Food Control, vol.26, issue.2, pp.401-415, 2012.
DOI : 10.1016/j.foodcont.2012.01.060

A. Hayat, C. Yang, A. Rhouati, M. , and J. , Recent Advances and Achievements in Nanomaterial-Based, and Structure Switchable Aptasensing Platforms for Ochratoxin A Detection, Sensors, vol.13, issue.11, pp.15187-15208, 2013.
DOI : 10.3390/s131115187

J. He, Y. Liu, M. Fan, and X. Liu, Isolation and Identification of the DNA Aptamer Target to Acetamiprid, Journal of Agricultural and Food Chemistry, vol.59, issue.5, pp.1582-1586, 2011.
DOI : 10.1021/jf104189g

Y. Helwa, N. Dave, R. Froidevaux, A. Samadi, and J. Liu, Aptamer-Functionalized Hydrogel Microparticles for Fast Visual Detection of Mercury(II) and Adenosine, ACS Applied Materials & Interfaces, vol.4, issue.4, pp.2228-2233, 1021.
DOI : 10.1021/am300241j

T. Hermann, P. , and D. J. , Adaptive Recognition by Nucleic Acid Aptamers, Science, vol.287, issue.5454, pp.820-825, 2000.
DOI : 10.1126/science.287.5454.820

T. Ihara, Y. Maruo, S. Takenaka, and M. Takagi, Ferrocene-oligonucleotide conjugates for electrochemical probing of DNA, Nucleic Acids Research, vol.24, issue.21, pp.4273-4280, 1996.
DOI : 10.1093/nar/24.21.4273

K. Ikebukuro, C. Kiyohara, and K. Sode, Novel electrochemical sensor system for protein using the aptamers in sandwich manner, Biosensors and Bioelectronics, vol.20, issue.10, 2005.
DOI : 10.1016/j.bios.2004.09.002

R. D. Jenison, S. C. Gill, A. Pardi, and B. Polisky, High-resolution molecular discrimination by RNA, Science, vol.263, issue.5152, pp.1425-1429, 1994.
DOI : 10.1126/science.7510417

S. Jeong, R. Paeng, and I. , Sensitivity and selectivity on aptamerbased assay: the determination of tetracycline residue in bovine milk, ScientificWorldJournal, vol.2012, pp.159456-159466, 2012.

M. Jo, J. Y. Ahn, J. Lee, S. Lee, S. W. Hong et al., Development of Single-Stranded DNA Aptamers for Specific Bisphenol A Detection, Oligonucleotides, vol.21, issue.2, pp.85-91, 2011.
DOI : 10.1089/oli.2010.0267

S. O. Kelley, J. K. Barton, N. M. Jackson, and M. G. Hill, Electrochemistry of Methylene Blue Bound to a DNA-Modified Electrode, Bioconjugate Chemistry, vol.8, issue.1, pp.31-37, 1021.
DOI : 10.1021/bc960070o

S. O. Kelley, N. M. Jackson, M. G. Hill, and J. K. Barton, Long-Range Electron Transfer through DNA Films, Angewandte Chemie International Edition, vol.38, issue.7, pp.941-945, 1999.
DOI : 10.1002/(SICI)1521-3773(19990401)38:7<941::AID-ANIE941>3.0.CO;2-7

M. Kim, H. Um, S. Bang, S. Lee, S. Oh et al., Arsenic Removal from Vietnamese Groundwater Using the Arsenic-Binding DNA Aptamer, Environmental Science & Technology, vol.43, issue.24, pp.9335-9340, 1021.
DOI : 10.1021/es902407g

S. E. Kim, W. Su, M. Cho, Y. Lee, and W. S. Choe, Harnessing aptamers for electrochemical detection of endotoxin, Analytical Biochemistry, vol.424, issue.1, 2012.
DOI : 10.1016/j.ab.2012.02.016

Y. J. Kim, Y. S. Kim, J. H. Niazi, and M. B. Gu, Electrochemical aptasensor for tetracycline detection, Bioprocess and Biosystems Engineering, vol.634, issue.2, pp.31-37, 2010.
DOI : 10.1007/s00449-009-0371-4

H. Lee, K. S. Kim, C. Kim, S. K. Hahn, J. et al., Electrical detection of VEGFs for cancer diagnoses using anti-vascular endotherial growth factor aptamer-modified Si nanowire FETs, Biosensors and Bioelectronics, vol.24, issue.6, pp.1801-1805, 2009.
DOI : 10.1016/j.bios.2008.08.036

S. Lee, Y. S. Kim, M. Jo, M. Jin, D. Lee et al., Chip-based detection of hepatitis C virus using RNA aptamers that specifically bind to HCV core antigen, Biochemical and Biophysical Research Communications, vol.358, issue.1, pp.47-52, 2007.
DOI : 10.1016/j.bbrc.2007.04.057

B. Li, Y. Wang, H. Wei, D. , and S. , Amplified electrochemical aptasensor taking AuNPs based sandwich sensing platform as a model, Biosensors and Bioelectronics, vol.23, issue.7, 2008.
DOI : 10.1016/j.bios.2007.09.019

L. Li, B. Li, Y. Qi, J. , and Y. , Label-free aptamer-based colorimetric detection of mercury ions in aqueous media using unmodified gold nanoparticles as colorimetric probe, Analytical and Bioanalytical Chemistry, vol.43, issue.8, pp.2051-2057, 2009.
DOI : 10.1007/s00216-009-2640-0

J. Liu, L. , and Y. , Adenosine-Dependent Assembly of Aptazyme-Functionalized Gold Nanoparticles and Its Application as a Colorimetric Biosensor, Analytical Chemistry, vol.76, issue.6, pp.1627-1632, 2004.
DOI : 10.1021/ac0351769

Y. Lu, X. Li, L. Zhang, P. Yu, L. Su et al., Aptamer-Based Electrochemical Sensors with Aptamer???Complementary DNA Oligonucleotides as Probe, Analytical Chemistry, vol.80, issue.6, pp.1883-1890, 1021.
DOI : 10.1021/ac7018014

P. O. Magalhaes, A. M. Lopes, P. G. Mazzola, C. Rangel-yagui, T. C. Penna et al., Methods of endotoxin removal from biological preparations: a review, J. Pharm. Pharm. Sci, vol.10, pp.388-404, 2007.

J. Mehta, B. Van-dorst, E. Rouah-martin, W. Herrebout, M. L. Scippo et al., In vitro selection and characterization of DNA aptamers recognizing chloramphenicol, Journal of Biotechnology, vol.155, issue.4, pp.361-369, 2011.
DOI : 10.1016/j.jbiotec.2011.06.043

M. Minunni, S. Tombelli, A. Gullotto, E. Luzi, and M. Mascini, Development of biosensors with aptamers as bio-recognition element: the case of HIV-1 Tat protein, Biosensors and Bioelectronics, vol.20, issue.6, pp.1149-1156, 2004.
DOI : 10.1016/j.bios.2004.03.037

M. Mir, M. Vreeke, and I. Katakis, Different strategies to develop an electrochemical thrombin aptasensor, Electrochemistry Communications, vol.8, issue.3, 2006.
DOI : 10.1016/j.elecom.2005.12.022

F. K. Muriuki, W. O. Ogara, F. M. Njeruh, and E. S. Mitema, Tetracycline residue levels in cattle meat from Nairobi salughter house in Kenya, J. Vet. Sci, vol.2, pp.97-101, 2001.

O. Sullivan and C. , Aptasensors ??? the future of biosensing?, Analytical and Bioanalytical Chemistry, vol.372, issue.1, pp.44-48, 2002.
DOI : 10.1007/s00216-001-1189-3

N. Paniel, J. Baudart, A. Hayat, and L. Barthelmebs, Aptasensor and genosensor methods for detection of microbes in real world samples, Methods, vol.64, issue.3, 2013.
DOI : 10.1016/j.ymeth.2013.07.001

K. Park, D. Kwon, and J. Kwak, Aptamer Based Electrochemical Sensor System for Protein Using the Generation/Collection Mode of Scanning Electrochemical Microscope (SECM), Journal of Nanoscience and Nanotechnology, vol.11, issue.5, pp.4305-4311, 2011.
DOI : 10.1166/jnn.2011.3671

A. L. Pena, C. M. Lino, and I. N. Silveira, Determination of oxytetracycline , tetracycline, and chlortetracycline in milk by liquid chromatography with postcolumn derivatization and fluorescence detection, J. AOAC Int, vol.82, pp.55-60, 1999.

C. G. Pheeney and J. K. Barton, DNA Electrochemistry with Tethered Methylene Blue, Langmuir, vol.28, issue.17, pp.7063-7070, 2012.
DOI : 10.1021/la300566x

A. E. Radi, J. L. Sanchez, E. Baldrich, O. Sullivan, and C. K. , Reagentless, Reusable, Ultrasensitive Electrochemical Molecular Beacon Aptasensor, Journal of the American Chemical Society, vol.128, issue.1, pp.117-124, 1021.
DOI : 10.1021/ja053121d

A. Rhouati, A. Hayat, D. B. Hernandez, Z. Meraihi, R. Munoz et al., Development of an automated flow-based electrochemical aptasensor for on-line detection of Ochratoxin A, Sensors and Actuators B: Chemical, vol.176, pp.1160-1166, 2013.
DOI : 10.1016/j.snb.2012.09.111

A. Rhouati, C. Yang, A. Hayat, M. , and J. , Aptamers: A Promosing Tool for Ochratoxin A Detection in Food Analysis, Toxins, vol.5, issue.11, p.10, 1988.
DOI : 10.3390/toxins5111988

N. C. Seeman, Nanomaterials Based on DNA, Annual Review of Biochemistry, vol.79, issue.1, pp.65-87, 2010.
DOI : 10.1146/annurev-biochem-060308-102244

A. Sett, S. Das, P. Sharma, and U. Bora, Aptasensors in Health, Environment and Food Safety Monitoring, Open Journal of Applied Biosensor, vol.01, issue.02, pp.9-19, 2012.
DOI : 10.4236/ojab.2012.12002

L. Shen, Z. Chen, Y. Li, S. He, S. Xie et al., Electrochemical DNAzyme Sensor for Lead Based on Amplification of DNA???Au Bio-Bar Codes, Analytical Chemistry, vol.80, issue.16, pp.6323-6328, 1021.
DOI : 10.1021/ac800601y

J. Sinha, S. J. Reyes, and J. P. Gallivan, Reprogramming bacteria to seek and destroy an herbicide, Nature Chemical Biology, vol.288, issue.6, pp.464-470, 2010.
DOI : 10.1038/nchembio.369

H. So, D. Park, E. Jeon, Y. Kim, B. S. Kim et al., Detection and titer estimation of Escherichia coli using aptamer-functionalized single-walled carbon-nanotube field-effect transistors, pp.197-201, 2008.

H. So, K. Won, Y. H. Kim, B. Kim, B. H. Ryu et al., Single-Walled Carbon Nanotube Biosensors Using Aptamers as Molecular Recognition Elements, Journal of the American Chemical Society, vol.127, issue.34, pp.11906-11907, 1021.
DOI : 10.1021/ja053094r

Y. Tang, B. Ge, D. Sen, Y. , H. Z. Parekh et al., Functional DNA switches: rational design and electrochemical signaling, Chem. Soc. Rev., vol.475, issue.2, pp.518-529, 2008.
DOI : 10.1039/C3CS60264H

S. Tombelli, M. Minunni, E. Luzi, and M. Mascini, Aptamer-based biosensors for the detection of HIV-1 Tat protein, Bioelectrochemistry, vol.67, issue.2, 2005.
DOI : 10.1016/j.bioelechem.2004.04.011

H. Wang, Z. Wu, L. Tang, R. Yu, and J. Jiang, Fluorescence protection assay: a novel homogeneous assay platform toward development of aptamer sensors for protein detection, Nucleic Acids Research, vol.39, issue.18, 2011.
DOI : 10.1093/nar/gkr559

L. Wang, X. Liu, Q. Zhang, C. Zhang, Y. Liu et al., Selection of DNA aptamers that bind to four organophosphorus pesticides, Biotechnology Letters, vol.28, issue.5, pp.869-874, 2012.
DOI : 10.1007/s10529-012-0850-6

R. J. White, N. Phares, A. A. Lubin, Y. Xiao, and K. W. Plaxco, Optimization of Electrochemical Aptamer-Based Sensors via Optimization of Probe Packing Density and Surface Chemistry, Langmuir, vol.24, issue.18, pp.10513-10518, 1021.
DOI : 10.1021/la800801v

I. Willner and M. Zayats, Electronic Aptamer-Based Sensors, Angewandte Chemie International Edition, vol.15, issue.34, pp.6408-6418, 2007.
DOI : 10.1002/anie.200604524

Z. S. Wu, M. M. Guo, S. B. Zhang, C. R. Chen, J. H. Jiang et al., Reusable Electrochemical Sensing Platform for Highly Sensitive Detection of Small Molecules Based on Structure-Switching Signaling Aptamers, Analytical Chemistry, vol.79, issue.7, pp.2933-2939, 2007.
DOI : 10.1021/ac0622936

H. Xiao, T. E. Edwards, F. Amaré, and A. R. , Structural Basis for Specific, High-Affinity Tetracycline Binding by an In Vitro Evolved Aptamer and Artificial Riboswitch, Chemistry & Biology, vol.15, issue.10, pp.1125-1137, 2008.
DOI : 10.1016/j.chembiol.2008.09.004

Y. Xiao, A. A. Lubin, A. J. Heeger, and K. W. Plaxco, Label-Free Electronic Detection of Thrombin in Blood Serum by Using an Aptamer-Based Sensor, Angewandte Chemie International Edition, vol.32, issue.34, pp.5456-5459, 2005.
DOI : 10.1002/anie.200500989

N. Yildirim, F. Long, C. Gao, M. He, H. C. Shi et al., Aptamer-Based Optical Biosensor For Rapid and Sensitive Detection of 17??-Estradiol In Water Samples, Environmental Science & Technology, vol.46, issue.6, pp.3288-3294, 1021.
DOI : 10.1021/es203624w

H. Yu, C. Luo, C. G. Sankar, and D. Sen, Voltammetric Procedure for Examining DNA-Modified Surfaces:?? Quantitation, Cationic Binding Activity, and Electron-Transfer Kinetics, Analytical Chemistry, vol.75, issue.15, pp.3902-3907, 1021.
DOI : 10.1021/ac034318w

J. Zhang, B. Zhang, Y. Wu, S. Jia, T. Fan et al., Fast determination of the tetracyclines in milk samples by the aptamer biosensor, The Analyst, vol.21, issue.10, pp.2706-2710, 1039.
DOI : 10.1039/c0an00237b

Y. L. Zhang, Y. Huang, J. H. Jiang, G. L. Shen, Y. et al., Electrochemical Aptasensor Based on Proximity-Dependent Surface Hybridization Assay for Single-Step, Reusable, Sensitive Protein Detection, Journal of the American Chemical Society, vol.129, issue.50, pp.15448-15449, 1021.
DOI : 10.1021/ja0773047

L. Zhou, D. Li, L. Gai, J. Wang, L. et al., Electrochemical aptasensor for the detection of tetracycline with multi-walled carbon nanotubes amplification, Sensors and Actuators B: Chemical, vol.162, issue.1, pp.201-208, 2012.
DOI : 10.1016/j.snb.2011.12.067

L. Zhou, J. Wang, D. Li, L. , and Y. , An electrochemical aptasensor based on gold nanoparticles dotted graphene modified glassy carbon electrode for label-free detection of bisphenol A in milk samples, Food Chemistry, vol.162, pp.34-40, 2014.
DOI : 10.1016/j.foodchem.2014.04.058